US$1,659.00
| brand | |
|---|---|
| Model Number | |
| weight | 10KG |
Any position for all valves except for type – 70 (without springs) that must be installed with hori-
Assembly position / location
zontal axis if operated by impulses.
Roughness index Ra 0,4 – flatness ratio 0,01/100 (ISO 110(1)
Subplate surface finishing
MTTFd values according to EN ISO 13849
75 years, for further details see technical table P007
Ambient temperature
Standard execution = -30°C + +70°C; /PE option = -20°C + +70°C; /BT option = 40°C + +70°C
NBR seals (standard) = -20°C + +60°C, with HFC hydraulic fluids = 20°C +50°C
Seals, recommended fluid temperature
FKM seals (/PE option)= -20°C + +80°C
HNBR seals (/BT option)= -40°C + +60°C, with HFC hydraulic fluids = -40°C + +50°C
Recommended viscosity
15+100 mm?/s – max allowed range 2.8 – 500 mm?s
Fluid contamination class
ISO 4406 class 21/19/16 NAS 1638 class 10, in line filtersof 25 um (B25 ≥75 recommended)
Hydraulic fluid
Suitable seals type
Clas sification
Ref. Standard
DIN 51524
NBR, FKM, HNBR
HL, HLP, HLPD, HVLP, HVLPD,
Mineral oils
FKM
Flame resistant without water
HEDU. HFDR
ISO 12922
NBR, HNBR
HFC
Flame resistant with water
Flow direction
As shown in the symbols of table 2
P, A, B, X = 350 bar (for pilot pressure see also option /L9 at section 45
T = 250 bar for external drain (standard)
Operating pressure
T and Y with internal drain (option /D) = 120 bar DPHI; 210 bar DPHE (D)C); 160 bar DPHE (AC)
Ports Y and L (if required): 0 bar
Minimum pilot pressure for correct operation is 8 bar
See diagrams QAp at section 6
Rated flow
DPH*-1: 160 I/min; DPH*-2: 300 I/min; DPH*-4: 700 I/min; DPH*-6: 1001/min
Maximum flow
(see rated flow at section 6 and operating limits at section 7)




We will contact you within 24 hours, please pay attention to the email from sales@profixshop.com.