Atos Valve DLKZA/UL-T-160-L71/NPT/BC 30 /PE

US$6,594.29

Additional information

brand

Model Number

weight

4.8kg

MAIN CHARACTERISTICS OF PROPORTIONAL DIRECTIONAL VALVES
Any position
Assembly position
Subplate surface finishing
Roughness index Ra 0,4 – flatness ratio 0,01/100 (ISO 1101)
-20°C + +70°C for -T execution; -20°C + +60°C for -TE and TES executions
Ambient temperature
Fluid
Hydraulic oil as per DIN 51524 … 535 for other fluids seee section 1
15 +100 mm?/s at 40°C (ISO VG 15+100)
Recommended viscosity
Fluid contamination class
ISO 4406 class 20/18/15 NAS 1638 class 9, in line filters of 10um (β10≥75 recommended)
-20°C +60°C (standard seals and water qlycol) -20°C+80°C (/PE seals)
Fluid temperature
DLHZO-T*
DLKZOR-T*
Valve model
Coil resistance R at 20°C
3+3.30
3.8 ÷ 4.1 Ω
Max, solenoid current
2.6 A
3A
35 Watt
40 Watt
Max. power
Insulation class
H (180°) Due to the occuring surface temperatures of the solenoid coils, the European standards
ISO 13732-1 and EN982 must be taken into account
Protection degree (CEI EN-60529)
IP65 for -T execution: IP67 for -TE and -TES executionns
Duty factor
Continuous rating (ED=100%)